ES-DC2 Dust Monitoring System for Solar Panel (Comparison Method)

ES-DC2  Dust Monitoring System for Solar Panel  is  a  method  to  quantify  the  impact  of  dust pollution on power generation efficiency by comparing the electrical performance parameters (such as short-circuit current, maximum power, etc.) of clean photovoltaic modules  그리고  dust-contaminated  modules.  Its  core  principle  is  to  calculate  the efficiency  loss  caused  ~에 의해  dust pollution by  measuring  the  difference  in  electrical performance  between  clean  modules  그리고  contaminated  modules  under  the  same conditions.

ES-DC2  Dust Monitoring System for Solar Panel is  a  method  to  quantify  the  impact  of  dust pollution on power generation efficiency by comparing the electrical performance parameters (such as short-circuit current, maximum power, etc.) of clean photovoltaic modules  그리고  dust-contaminated  modules.  Its  core  principle  is  to  calculate  the efficiency  loss  caused  ~에 의해  dust pollution by  measuring  the  difference  in  electrical performance  between  clean  modules  그리고  contaminated  modules  under  the  same conditions.

ES-DC2 dust  index  meter  is  suitable  ~을 위한  photovoltaic  panels  ~와 함께  a maximum adaptability of 30A, 50V and 700W . The included SMD Pt100RTD is used for the backside temperature measurement of the photovoltaic panel , and the output is via Modbus RTU (RS485) .

Measuring principle

그만큼  main  principle  of  the  reference  method  ~을 위한  measuring  the  pollution  of photovoltaic modules is as follows: two photovoltaic modules of the same model batch are set up and placed in the same environment, one is kept clean and the other accumulates dust naturally. According to IEC 60904, the effective irradiance of the two photovoltaic modules is calculated by measuring the short-circuit current and the back temperature of the module. The pollution loss is calculated by comparing the effective irradiance of the polluted photovoltaic module with the effective irradiance of the clean reference photovoltaic module. The calculation formula of the pollution loss index SLI is as follows:

SLI =  (1-Geffs/Geffc)  ×  100%.  Geffs  is  the  effective  irradiance  calculated  from  the contaminated components, and Geffc is the effective irradiance calculated from the clean components.

Product Parameters

Parameter Description

Defacement rate

0  ~ 100%

해결

0. 1 %

측정 정확도

1%

Component temperature measurement range

-40  ~+150℃

Component temperature measurement accuracy

±(0. 15 + 0.002t) °C

Component temperature probe

PT100 Class A

Maximum short-circuit current of the component under test

30A

Maximum open circuit voltage of the component under test

50V

Reference Standards

EIC 61724-1(2021)

전원 공급 범위

12~24V DC

최대 전력 소비량

20mA @12V DC

Output signal form

RS485 standard modbus protocol

작동 온도

-40℃~+70℃

작동 습도

0-100%RH

보관 온도

-50-85℃

Instrument size

283*165*66mm (width excluding waterproof joint)

무게

2.3KG

Waterproof grade

IP65

서류

다음 단계로 나아가세요

견적 받기

귀하의 특정 요구 사항에 따라 견적을 요청하세요

유통업체가 되려면

귀하 지역에서 센텍 브랜드를 유통하고 싶으시다면, 자세한 내용을 문의해 주세요.

설치 및 유지 관리

전문 엔지니어 그룹이 센서 설치 및 유지관리를 도와드립니다.

연락하세요!