ES-DC2 Dust Monitoring System for Solar Panel (Comparison Method)

ES-DC2 Dust Monitoring System for Solar Panel utilizes module-to-module extreme value data analysis (IEC 61724 contamination measurement method) technology, making it easy to install in new or existing PV arrays and integrate into the power plant management system. The monitoring sensor is installed on two PV panel samples in the field (one panel is naturally dusted, and the other is regularly cleaned). By continuously measuring the power loss caused by contaminants on the glass, the amount of reduced sunlight reaching the solar module is calculated.

Contaminants on solar module glass are one of the major problems rapidly impacting photovoltaic (PV) power plants, reducing power generation efficiency and cost-effectiveness. Dust contamination can significantly reduce PV power generation, estimated at least 5% annually.

ES-DC2 Dust Monitoring System for Solar Panel utilizes module-to-module extreme value data analysis (IEC 61724 contamination measurement method) technology, making it easy to install in new or existing PV arrays and integrate into the power plant management system. The monitoring sensor is installed on two PV panel samples in the field (one panel is naturally dusted, and the other is regularly cleaned). By continuously measuring the power loss caused by contaminants on the glass, the amount of reduced sunlight reaching the solar module is calculated.

By measuring the proportion of contaminants (SR), this is converted into a real-time loss of power generation. This allows maintenance personnel to know when contamination reaches a critical point and when it is necessary to initiate a cleaning procedure. The product requires no maintenance; it is cleaned in the same way as surrounding modules.

Product Parameters

Parameter Description

Remark

Measured parameters

Contamination ratio, cleanliness ratio

 

Measured range

Pollution rate 50-100%

 

Measurement accuracy of pollution ratio

Dual sensor value 50~80%

Measurement accuracy ±5%,Processed by internal sophisticated algorithms

Measurement range 90~100%

Measurement range 80~90%

استقرار

Better than full range by 1% (per year)

 

Backplane Temperature Sensor

Measurement range: -50~150°C

Accuracy: 0.3°C

Output Method

RS485 Modbus(wired); 4G/Bluetooth (wireless)

 

Control methods

normally open/normally closed, cyclic control, time control, manual control

 

Operating voltage

DC12~24V

 

Current range

70~200mA @DC12V

 

استهلاك الطاقة

3W @ DC12V

 

درجة حرارة التشغيل

-40°C ~ +60°C

 

مستوى الحماية

IP65

 

وزن

4Kg

Net weight

أبعاد

500×400×200mm

Net size

Sensor cable length

20m

 

Calibrate photovoltaic panels

2pcs

 

Monitoring probe

with dual-channel sensor data acquisition

 

Threshold alarm

upper limit, lower limit, and linkage with secondary equipment.

 

Component temperature

PT100 Class A platinum resistance thermometer

 

The observation timeframe

threshold meets the monitoring requirements.

 

وثائق

اتخذ الخطوة التالية

احصل على عرض أسعار

اطلب عرض أسعار منا بناءً على متطلباتك المحددة

أن تكون موزعًا

إذا كنت ترغب في توزيع العلامة التجارية Sentec في منطقتك المحلية، فيمكنك الاتصال بنا لمزيد من المعلومات.

التركيب والصيانة

مجموعة من المهندسين المحترفين هنا لمساعدتك في تركيب وصيانة أجهزة الاستشعار الخاصة بك.

احصل على اتصال!