ES-DC2 Dust Monitoring System for Solar Panel (Comparison Method)

ES-DC2  Dust Monitoring System for Solar Panel  is  a  method  to  quantify  the  impact  of  dust pollution on power generation efficiency by comparing the electrical performance parameters (such as short-circuit current, maximum power, etc.) of clean photovoltaic modules  और  dust-contaminated  modules.  Its  core  principle  is  to  calculate  the efficiency  loss  caused  द्वारा  dust pollution by  measuring  the  difference  in  electrical performance  between  clean  modules  और  contaminated  modules  under  the  same conditions.

ES-DC2  Dust Monitoring System for Solar Panel is  a  method  to  quantify  the  impact  of  dust pollution on power generation efficiency by comparing the electrical performance parameters (such as short-circuit current, maximum power, etc.) of clean photovoltaic modules  और  dust-contaminated  modules.  Its  core  principle  is  to  calculate  the efficiency  loss  caused  द्वारा  dust pollution by  measuring  the  difference  in  electrical performance  between  clean  modules  और  contaminated  modules  under  the  same conditions.

ES-DC2 dust  index  meter  is  suitable  के लिए  photovoltaic  panels  साथ  a maximum adaptability of 30A, 50V and 700W . The included SMD Pt100RTD is used for the backside temperature measurement of the photovoltaic panel , and the output is via Modbus RTU (RS485) .

Measuring principle

The  main  principle  of  the  reference  method  के लिए  measuring  the  pollution  of photovoltaic modules is as follows: two photovoltaic modules of the same model batch are set up and placed in the same environment, one is kept clean and the other accumulates dust naturally. According to IEC 60904, the effective irradiance of the two photovoltaic modules is calculated by measuring the short-circuit current and the back temperature of the module. The pollution loss is calculated by comparing the effective irradiance of the polluted photovoltaic module with the effective irradiance of the clean reference photovoltaic module. The calculation formula of the pollution loss index SLI is as follows:

SLI =  (1-Geffs/Geffc)  ×  100%.  Geffs  is  the  effective  irradiance  calculated  from  the contaminated components, and Geffc is the effective irradiance calculated from the clean components.

Product Parameters

Parameter Description

Defacement rate

0  ~ 100%

संकल्प

0. 1 %

माप सटीकता

1%

Component temperature measurement range

-40  ~+150℃

Component temperature measurement accuracy

±(0. 15 + 0.002t) °C

Component temperature probe

PT100 Class A

Maximum short-circuit current of the component under test

30A

Maximum open circuit voltage of the component under test

50V

Reference Standards

EIC 61724-1(2021)

बिजली आपूर्ति रेंज

12~24V DC

अधिकतम बिजली खपत

20mA @12V DC

Output signal form

RS485 standard modbus protocol

परिचालन तापमान

-40℃~+70℃

परिचालन आर्द्रता

0-1001टीपी3टीआरएच

भंडारण तापमान

-50-85℃

Instrument size

283*165*66mm (width excluding waterproof joint)

वज़न

2.3KG

Waterproof grade

आईपी65

दस्तावेज़

अगला कदम उठाएँ

एक कहावत कहना

अपनी विशिष्ट आवश्यकताओं के आधार पर हमसे उद्धरण का अनुरोध करें

वितरक बनें

यदि आप अपने स्थानीय क्षेत्र में सेंटेक ब्रांड का वितरण करना चाहते हैं, तो आप हमसे अधिक जानकारी के लिए संपर्क कर सकते हैं।

स्थापना और रखरखाव

पेशेवर इंजीनियरों का एक समूह आपके सेंसर की स्थापना और रखरखाव में मदद करने के लिए यहां मौजूद है।

संपर्क करें!