ES-DC2 Dust Monitoring System for Solar Panel (Comparison Method)

ES-DC2  Dust Monitoring System for Solar Panel  is  a  method  to  quantify  the  impact  of  dust pollution on power generation efficiency by comparing the electrical performance parameters (such as short-circuit current, maximum power, etc.) of clean photovoltaic modules  و  dust-contaminated  modules.  Its  core  principle  is  to  calculate  the efficiency  loss  caused  بواسطة  dust pollution by  measuring  the  difference  in  electrical performance  between  clean  modules  و  contaminated  modules  under  the  same conditions.

ES-DC2  Dust Monitoring System for Solar Panel is  a  method  to  quantify  the  impact  of  dust pollution on power generation efficiency by comparing the electrical performance parameters (such as short-circuit current, maximum power, etc.) of clean photovoltaic modules  و  dust-contaminated  modules.  Its  core  principle  is  to  calculate  the efficiency  loss  caused  بواسطة  dust pollution by  measuring  the  difference  in  electrical performance  between  clean  modules  و  contaminated  modules  under  the  same conditions.

ES-DC2 dust  index  meter  is  suitable  ل  photovoltaic  panels  مع  a maximum adaptability of 30A, 50V and 700W . The included SMD Pt100RTD is used for the backside temperature measurement of the photovoltaic panel , and the output is via Modbus RTU (RS485) .

Measuring principle

ال  main  principle  of  the  reference  method  ل  measuring  the  pollution  of photovoltaic modules is as follows: two photovoltaic modules of the same model batch are set up and placed in the same environment, one is kept clean and the other accumulates dust naturally. According to IEC 60904, the effective irradiance of the two photovoltaic modules is calculated by measuring the short-circuit current and the back temperature of the module. The pollution loss is calculated by comparing the effective irradiance of the polluted photovoltaic module with the effective irradiance of the clean reference photovoltaic module. The calculation formula of the pollution loss index SLI is as follows:

SLI =  (1-Geffs/Geffc)  ×  100%.  Geffs  is  the  effective  irradiance  calculated  from  the contaminated components, and Geffc is the effective irradiance calculated from the clean components.

Product Parameters

Parameter Description

Defacement rate

0  ~ 100%

دقة

0. 1 %

دقة القياس

1%

Component temperature measurement range

-40  ~+150℃

Component temperature measurement accuracy

±(0. 15 + 0.002t) °C

Component temperature probe

PT100 Class A

Maximum short-circuit current of the component under test

30A

Maximum open circuit voltage of the component under test

50V

Reference Standards

EIC 61724-1(2021)

نطاق مصدر الطاقة

12~24V DC

الحد الأقصى لاستهلاك الطاقة

20mA @12V DC

Output signal form

RS485 standard modbus protocol

درجة حرارة التشغيل

-40℃~+70℃

رطوبة التشغيل

0-100%RH

درجة حرارة التخزين

-50-85℃

Instrument size

283*165*66mm (width excluding waterproof joint)

وزن

2.3KG

Waterproof grade

IP65

وثائق

اتخذ الخطوة التالية

احصل على عرض أسعار

اطلب عرض أسعار منا بناءً على متطلباتك المحددة

أن تكون موزعًا

إذا كنت ترغب في توزيع العلامة التجارية Sentec في منطقتك المحلية، فيمكنك الاتصال بنا لمزيد من المعلومات.

التركيب والصيانة

مجموعة من المهندسين المحترفين هنا لمساعدتك في تركيب وصيانة أجهزة الاستشعار الخاصة بك.