ES-W3600 Online Dust Monitoring Station

The ES-W3600 pump-sampling Online Dust Monitoring Station is a high-tech product integrating aerodynamics, digital signal processing, and optoelectronics. Primarily designed to measure atmospheric dust mass concentrations (PM2.5, PM10, and TSP), it supports the optional monitoring of meteorological parameters such as noise, ambient temperature, relative humidity, wind speed, and wind direction, serving as a core module for air quality monitoring systems

The ES-W3600 pump-sampling Online Dust Monitoring Station is a high-tech product integrating aerodynamics, digital signal processing, and optoelectronics. Primarily designed to measure atmospheric dust mass concentrations (PM2.5, PM10, and TSP), it supports the optional monitoring of meteorological parameters such as noise, ambient temperature, relative humidity, wind speed, and wind direction, serving as a core module for air quality monitoring systems. It is widely applicable in sectors including environmental protection, chemical engineering, scenic areas, and parks.

Operating power supply

Напряжение

DC  12V-36V(max.100mV ripple)

Current

≦250mA

Потребляемая мощность

2W

Monitoring parameter

Particle size parameters

PM2.5, PM10, and TSP

Working methods

Continuous online monitoring

Police reporting

Status indicator light alarm, buzzer alarm (optional, turned off by default)

Data Communication

Output Methods

RS485, GPRS, 4G wireless (direct data viewing via mobile phone—free software—or data retrieval via API).

Data Updates

Default operating modes:

1. When the particulate matter sensor is running, internal data updates once per second; when not running, the data remains the last set recorded during the previous operation.

2. Request-response (polling) or active reporting.

Метод отображения

3.2-inch LCD display, local LED screen, remote LED screen, etc., remote mobile app and PC software display, API calls.

Service life

> 25,000 hours at 50°C (continuous use for over 3 years)

Повторяемость

≤10% (recommended if usage requirements are met)

Air pump noise

<55(dB/A)

Operating temperature and humidity

-10~60°C, Humidity: 0~90% RH (non-condensing)

Temperature and humidity storage

-20~80°C, Humidity: 0~90%RH.

External dimensions

20*35*50 (L*W*H, unit: mm)

Масса

Approximately 4KG (including case)

Standard accessories

8P 1 piece of terminal wire

PM value detection related parameters

Диапазон измерения

Принцип

Laser scattering method

Тип

Industrial particulate matter sensors

PM2.5

0-2mg/m³

PM10

0-4mg/m³

ТСП

0-30mg/m³

Ambient temperature

-40-80℃

Optional (Ultrasonic Integrated Micro-Weather Station) Temperature: -40–60°C, 0.01°C, ±0.3°C (at 25°C)

Relative Humidity: 0–100% RH, 0.01%, ±3% RH

Wind Speed: 0–60 m/s, 0.01 m/s, ±0.3 m/s or ±3% (0–30 m/s), Ultrasonic

Wind Direction: 0–360°, 0.1°, ±2°, Ultrasonic

Atmospheric Pressure: 300–1100 hPa, 0.1 hPa, ±0.5 hPa (0–30°C)

Относительная влажность

0-100%RH

Атмосферное давление

300-1100hPa

Скорость ветра

0-40m/s

Направление ветра

0-360°

Output resolution

0.1 μg/m³

Точность измерения

PM2.5

≤±10%;(25℃

PM10

≤±20%;(25℃

ТСП

≤±20%;(25℃

Ambient temperature

±0.3℃

Относительная влажность

±3%RH

Скорость ветра

± (0.3 + 0.03V) m/s V indicates wind speed

Направление ветра

±4 °

Sampling method

Air pump guided flow type

Air pump flow

2 liters/minute, customizable according to customer flow requirements

Источник света

Laser diodes

Документы

Сделайте следующий шаг

Получить предложение

Запросите у нас расценки на основе ваших конкретных требований

Быть дистрибьютором

Если вы хотите распространять продукцию бренда Sentec в вашем регионе, свяжитесь с нами для получения дополнительной информации.

Установка и обслуживание

Группа профессиональных инженеров готова помочь вам с установкой и обслуживанием датчика.

Связаться!