ES-W3600 Online Dust Monitoring Station

The ES-W3600 pump-sampling Online Dust Monitoring Station is a high-tech product integrating aerodynamics, digital signal processing, and optoelectronics. Primarily designed to measure atmospheric dust mass concentrations (PM2.5, PM10, and TSP), it supports the optional monitoring of meteorological parameters such as noise, ambient temperature, relative humidity, wind speed, and wind direction, serving as a core module for air quality monitoring systems

The ES-W3600 pump-sampling Online Dust Monitoring Station is a high-tech product integrating aerodynamics, digital signal processing, and optoelectronics. Primarily designed to measure atmospheric dust mass concentrations (PM2.5, PM10, and TSP), it supports the optional monitoring of meteorological parameters such as noise, ambient temperature, relative humidity, wind speed, and wind direction, serving as a core module for air quality monitoring systems. It is widely applicable in sectors including environmental protection, chemical engineering, scenic areas, and parks.

Operating power supply

Stromspannung

DC  12V-36V(max.100mV ripple)

Current

≦250mA

Energieaufnahme

2W

Monitoring parameter

Particle size parameters

PM2.5, PM10, and TSP

Working methods

Continuous online monitoring

Police reporting

Status indicator light alarm, buzzer alarm (optional, turned off by default)

Data Communication

Output Methods

RS485, GPRS, 4G wireless (direct data viewing via mobile phone—free software—or data retrieval via API).

Data Updates

Default operating modes:

1. When the particulate matter sensor is running, internal data updates once per second; when not running, the data remains the last set recorded during the previous operation.

2. Request-response (polling) or active reporting.

Anzeigemethode

3.2-inch LCD display, local LED screen, remote LED screen, etc., remote mobile app and PC software display, API calls.

Service life

> 25,000 hours at 50°C (continuous use for over 3 years)

Wiederholbarkeit

≤10% (recommended if usage requirements are met)

Air pump noise

<55(dB/A)

Operating temperature and humidity

-10~60°C, Humidity: 0~90% RH (non-condensing)

Temperature and humidity storage

-20~80°C, Humidity: 0~90%RH.

External dimensions

20*35*50 (L*W*H, unit: mm)

Gewicht

Approximately 4KG (including case)

Standard accessories

8P 1 piece of terminal wire

PM value detection related parameters

Messbereich

Prinzip

Laser scattering method

Typ

Industrial particulate matter sensors

PM2.5

0-2mg/m³

PM10

0-4mg/m³

TSP

0-30mg/m³

Ambient temperature

-40-80℃

Optional (Ultrasonic Integrated Micro-Weather Station) Temperature: -40–60°C, 0.01°C, ±0.3°C (at 25°C)

Relative Humidity: 0–100% RH, 0.01%, ±3% RH

Wind Speed: 0–60 m/s, 0.01 m/s, ±0.3 m/s or ±3% (0–30 m/s), Ultrasonic

Wind Direction: 0–360°, 0.1°, ±2°, Ultrasonic

Atmospheric Pressure: 300–1100 hPa, 0.1 hPa, ±0.5 hPa (0–30°C)

Relative Luftfeuchtigkeit

0-100%RH

Luftdruck

300-1100hPa

Windgeschwindigkeit

0-40m/s

Windrichtung

0-360 °

Output resolution

0.1 μg/m³

Messgenauigkeit

PM2.5

≤±10%;(25℃

PM10

≤±20%;(25℃

TSP

≤±20%;(25℃

Ambient temperature

±0.3℃

Relative Luftfeuchtigkeit

±3%RH

Windgeschwindigkeit

± (0.3 + 0.03V) m/s V indicates wind speed

Windrichtung

±4 °

Sampling method

Air pump guided flow type

Air pump flow

2 liters/minute, customizable according to customer flow requirements

Lichtquelle

Laser diodes

Unterlagen

Machen Sie den nächsten Schritt

Ein Angebot einholen

Fordern Sie bei uns ein Angebot basierend auf Ihren spezifischen Anforderungen an

Vertriebspartner werden

Wenn Sie die Marke Sentec in Ihrer Region vertreiben möchten, können Sie uns für weitere Informationen kontaktieren.

Installation und Wartung

Eine Gruppe professioneller Ingenieure steht Ihnen bei der Installation und Wartung Ihres Sensors zur Seite.

Kontakt aufnehmen!