ES-DC1 PV Soiling Dust Monitoring System

The ES-DC1 PV soiling dust monitoring system is primarily used in PV arrays within solar power plants, installed on the frame of the PV panels. This system monitors dust accumulation on the power plant surface in real time, providing a scientific basis for cleaning and maintenance through intelligent data analysis.

For photovoltaic (PV) power generation systems operating for extended periods, dust accumulation on solar panels directly impacts power generation efficiency. Dust on the panel surface reflects, scatters, and absorbs solar radiation, significantly reducing solar transmittance and consequently decreasing the amount of solar radiation received by the panel, thus lowering the output power.

The ES-DC1 PV soiling dust monitoring system is primarily used in PV arrays within solar power plants, installed on the frame of the PV panels. This system monitors dust accumulation on the power plant surface in real time, providing a scientific basis for cleaning and maintenance through intelligent data analysis. Suitable for PV power plants of all sizes, whether large centralized or distributed, it effectively improves power generation efficiency and reduces operation and maintenance costs, making it an indispensable intelligent management tool for the PV industry.

Product Parameters

Parameter Description

Remark

Contamination Ratio

Dual sensor value 50~100%

 

Measurement range 90~100%

Measurement accuracy ±1%+ 1%FS of reading

Measurement range 80~90%

Measurement accuracy ±2%

Contamination Ratio Measurement Accuracy

Measurement range 50~80%

Measurement accuracy ±5%,Processed by internal sophisticated algorithms

Stabiliteit

Better than full range by 1% (per year)

 

Backplane Temperature Sensor

Measurement range: -50~150°C
Accuracy: 0.2°C
Resolution: 0.1°C

Optioneel

GPS Positioning

Operating voltage: 3.3V-5V

Operating current: 40-80mA

Positioning accuracy: Average 10m

Optioneel

Output Method

RS485 Modbus

 

Linked Output (Passive Normally Open Contact)

Generally used to connect cleaning equipment, relay

Alarm threshold

Upper and Lower Thresholds Can Be Set

 

Operating voltage

DC12V(Permissible Voltage Range DC9~30V)

 

Current range

70~200mA @DC12V

 

Maximaal stroomverbruik

<2.5W@DC12V

Low power design

Bedrijfstemperatuur

-40°C ~ +60°C

 

Bedrijfsvochtigheid

0 ~ 90%RH

 

Gewicht

3.5Kg

Net weight

Afmetingen

900mm*170mm*42mm

Net size

Sensor cable length

20m

 

Documenten

Zet de volgende stap

Vraag een offerte aan

Vraag bij ons een offerte aan op basis van uw specifieke wensen

Distributeur worden

Wilt u het merk sentec in uw regio distribueren, neem dan contact met ons op.

Installatie en onderhoud

Een team van professionele ingenieurs staat klaar om u te helpen bij de installatie en het onderhoud van uw sensoren.

Neem contact op!