Pluviômetro de balde basculante ABS ES-R404

ES-R404 ABS tipping bucket rain gauge is a precipitation measurement instrument, and its performance meets the requirements of the national standard GB/T 21978.2-2014 “Precipitation Observation Requirements”.
The core component of the instrument, the tipping bucket, adopts a three-dimensional streamlined design, which makes the tipping bucket turn water more smoothly, and has the functions of self-cleaning dust and easy cleaning. The rainfall can be directly read, without the need for secondary calculation, which is simple and convenient.

ES-R404 ABS tipping bucket rain gauge is a precipitation measurement instrument, and its performance meets the requirements of the national standard GB/T 21978.2-2014 “Precipitation Observation Requirements”.
The core component of the instrument, the tipping bucket, adopts a three-dimensional streamlined design, which makes the tipping bucket turn water more smoothly, and has the functions of self-cleaning dust and easy cleaning. The rainfall can be directly read, without the need for secondary calculation, which is simple and convenient.

The tipping bucket of the instrument is equipped with a constant magnet steel, and the reed switch bracket is equipped with a reed switch. When the instrument leaves the factory, the magnetic steel and the reed switch have been adjusted to a suitable coupling distance, so that the output signal of the instrument is proportional to the number of times the tipping bucket is turned over relation.

Rain gauge cylinder diameter

Φ200mm

Resolução

default 0.2mm, optional 0.5mm

Cutting edge acute angle

40°~45°

Measurement error

≤±3% (indoor artificial precipitation, subject to the discharge of the instrument itself)

Rain intensity range

0mm~4mm/min (maximum rain intensity allowed to pass 8mm/min)

Output model

4~20mA/0~2V/0~5V/0~10V, pulse type, 485 communication (standard MODBUS-RTU protocol)

Faixa de fornecimento de energia

4.5~30V

Consumo máximo de energia

0.24W

Ambiente de trabalho

0~50℃, <95%(40℃)

Storage environment

-40~125°C, <80% (non-condensing)

Withstand voltage

≤100V (pulse type)

Withstand current

≤0.5A (pulse type)

Documentos

Dê o próximo passo

Obter uma cotação

Solicite um orçamento com base em suas necessidades específicas

Para ser um distribuidor

Se você quiser distribuir a marca Sentec em sua área local, entre em contato conosco para saber mais.

Instalação e Manutenção

Um grupo de engenheiros profissionais está aqui para ajudar na instalação e manutenção do seu sensor.

Entre em contato!