Pluviómetro de cubeta basculante ES-R404 ABS

ES-R404 ABS tipping bucket rain gauge is a precipitation measurement instrument, and its performance meets the requirements of the national standard GB/T 21978.2-2014 “Precipitation Observation Requirements”.
The core component of the instrument, the tipping bucket, adopts a three-dimensional streamlined design, which makes the tipping bucket turn water more smoothly, and has the functions of self-cleaning dust and easy cleaning. The rainfall can be directly read, without the need for secondary calculation, which is simple and convenient.

ES-R404 ABS tipping bucket rain gauge is a precipitation measurement instrument, and its performance meets the requirements of the national standard GB/T 21978.2-2014 “Precipitation Observation Requirements”.
The core component of the instrument, the tipping bucket, adopts a three-dimensional streamlined design, which makes the tipping bucket turn water more smoothly, and has the functions of self-cleaning dust and easy cleaning. The rainfall can be directly read, without the need for secondary calculation, which is simple and convenient.

The tipping bucket of the instrument is equipped with a constant magnet steel, and the reed switch bracket is equipped with a reed switch. When the instrument leaves the factory, the magnetic steel and the reed switch have been adjusted to a suitable coupling distance, so that the output signal of the instrument is proportional to the number of times the tipping bucket is turned over relation.

Rain gauge cylinder diameter

Φ200mm

Resolución

default 0.2mm, optional 0.5mm

Cutting edge acute angle

40°~45°

Measurement error

≤±3% (indoor artificial precipitation, subject to the discharge of the instrument itself)

Rain intensity range

0mm~4mm/min (maximum rain intensity allowed to pass 8mm/min)

Output model

4~20mA/0~2V/0~5V/0~10V, pulse type, 485 communication (standard MODBUS-RTU protocol)

Gama de fuentes de alimentación

4.5~30V

Consumo máximo de energía

0.24W

Entorno de trabajo

0~50℃, <95%(40℃)

Storage environment

-40~125°C, <80% (non-condensing)

Withstand voltage

≤100V (pulse type)

Withstand current

≤0.5A (pulse type)

Documentos

Da el siguiente paso

Obtenga una cotización

Solicite una cotización basada en sus necesidades específicas.

Ser Distribuidor

Si desea distribuir la marca sentec en su área local, puede contactarnos para obtener más información.

Instalación y mantenimiento

Un grupo de ingenieros profesionales está aquí para ayudarle con la instalación y el mantenimiento de sus sensores.

¡Contacta con nosotros!