ES-A227 Solar shield air and gas sensor

ES-A227 integrated shutter solar shield air and gas sensor can be widely used in environmental detection, supporting monitoring of temperature and humidity, atmospheric pressure, light, noise, CO2, PM2.5 and PM10, TVOC, formaldehyde (CH2O), ozone (O3), oxygen (O2), hydrogen sulfide (H2S), methane (CH4), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), hydrogen (H2), ammonia (NH3) and other parameters.

ES-A227 integrated shutter solar shield air and gas sensor can be widely used in environmental detection, supporting monitoring of temperature and humidity, atmospheric pressure, light, noise, CO2, PM2.5 and PM10, TVOC, formaldehyde (CH2O), ozone (O3), oxygen (O2), hydrogen sulfide (H2S), methane (CH4), carbon monoxide (CO), nitrogen dioxide (NO2), sulfur dioxide (SO2), hydrogen (H2), ammonia (NH3) and other parameters. The sensor is installed in the shutter box, and the shutter box shell can protect the internal meteorological sensor from strong wind, rain and snow. At the same time, the whole machine is designed in the shape of white shutters to avoid the influence of solar radiation energy to the greatest extent, ensuring that the air inside and outside the equipment can circulate and interact with each other, thereby ensuring the accuracy and stability of the measurement data, greatly extending the service life of meteorological instruments, and reducing maintenance costs. It is an indispensable equipment in meteorological observation. The equipment adopts the standard MODBUS-RTU communication protocol and RS485 signal output, and the maximum communication distance can reach 2000 meters.

Parameters

Range

Resolution

Accuracy

Temperature

-40℃~+120℃

0.1°C

±0.5°C(25°C)

Humidity

0~100%RH

0.1%RH

±3%RH(60%RH,25℃)

Atmospheric pressure

0~120Kpa

0.1Kpa

±0.15Kpa@25℃75Kpa

Illuminance

0-200,000 Lux

1Lux

±7%(25℃)

Noise

30-130db

±3%F.S

0.3dB

PM2.5 / PM10/PM1.0

0~1000ug/m3

±10%

±10%C(25°C)

TSP/PM100

0~20000ug/m3

±3%F.S

1ug/m4

TVOC

0~60000ppb

1ppb

±8%FS±125ppb

CO2

0~5000ppm

1ppm

±(40ppm+ 3%F·S)

Formaldehyde

0~5ppm

0.01ppm

±5%FS

Ozone

0~10ppm

0.01ppm

±6%FS

O2

0~25%Vol

0.1%Vol

±3%FS

H2S

0~100ppm

1ppm

±3%FS

CH4

0~100%LEL

1%LEL

±5%FS

CO

0~1000ppm

1ppm

±3%FS

NO2

0~20ppm

0.1ppm

±3%FS

SO2

0~20ppm

0.1ppm

±3%FS

H2

0~1000ppm

1ppm

±3%FS

NH3

0~100ppm

1ppm

±2%FS

Power supply

DC 10-30V(default)

Power consumption

0.8W

Work environment

Temperature - 10 ℃ - 55 ℃; humidity 0 ~ 95% RH, non condensing

Signal output

RS485 output (standard Modbus RTU protocol), analoge output, RJ45,4G, Lora, WIFI

Product material

ABS

Installation method

Bracket installation

Documents

Take the next step

Get a Quote

Request a quote from us based on your specific requirements

To be a Distributor

If you want to distribute sentec brand in your local area, you can contact us for more.

Installation & Maintain

A group of  professional engineer is here to help your sensor installation & maintenance.

احصل على اتصال!